Loading...
What if...
67
Troubleshooting
Connect Milk Shuttle II to the mains voltage
for charging immediately.
Allow the medium in the MilkShuttle to cool
to below 70 °C (158 °F).
Add cold milk or cold water until the medium
has cooled to under 70 °C (158 °F).
Plug the MilkShuttle's power connector into
the mains power supply as soon as possible
so that the nearly empty battery can be
recharged.
Fault description
Dosing pump operating has been attempted.
However, the current voltage of battery 1 is too
low (< 12.0 V) in order to start the pump
(functionality available as of firmware version
1.06).
The medium in the MilkShuttle (milk, water)
has a temperature of over 70 °C (= 158 °F).
The dosing pump will not operate in order to
prevent material damage or scalding
(functionality available as of firmware version
1.06).
The MilkShuttle is to be moved using the
propelling drive. The current voltage of battery
1 is however too low to move the MilkShuttle.
(functionality available as of firmware version
1.07).
The MilkShuttle is to be moved using the
propelling drive. The current voltage of battery
2is however too low to move the MilkShuttle.
(functionality available as of firmware version
1.07).
Display message
91 Fault
Battery low!
92 Fault
Temperature
93 Fault
Battery low
94 Fault
Battery low
No.
Type
91
1
92
1
93
1
94
1

Table of Contents