vacon • 35 Parameter description
3
The parameter sets the speed variation (as % of nominal speed) when the motor is at 100%
load. Normally droop action is decreased when the motor is running at low speed. Parameter
P9.9 allows to set a speed independent droop.
P1.10 M
OTOR IDENTIFICATION
This procedure measures motor stator resistance and automatically sets U/f characteristic, to
obtain good torque also at low speed.
0: not active
1: standstill identification
Run command must be given and hold high within 20s after programming the value 1. The mo-
tor does not rotate and the drive will automatically exit run state at the end of the measure-
ments.
Procedure sets the following parameters: P9.3, P9.4, P9.5, P9.6, P9.7.
Also speed control (P1.8 =1) is activated.
Note: optimized U/f settings will cause motor current values comparable to nominal one, also
at very low speed. External cooling of the motor is needed if the motor works in this condition
for significant time.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vacon 20 SERIES and is the answer not in the manual?

Vacon 20 SERIES Specifications

General IconGeneral
Output Voltage0 to Input Voltage
Storage Temperature-40°C to +70°C
DimensionsVaries by model
WeightVaries by model
Power Range0.25 kW to 18.5 kW
Voltage Range200 V to 480 V
Control MethodSensorless vector control
Protection ClassIP20
Ambient Temperature-10°C to +50°C
Communication OptionsModbus, CANopen
EMC FilterIntegrated
STO (Safe Torque Off)Yes
Input Voltage208-240 V, 380-480 V
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Overtemperature
Operating Temperature-10°C to +50°C
Humidity5% to 95% non-condensing