vacon • 47 Parameter description
3
3.8 Supervisions
P8.1 RUNNING FEEDBACK TOLERANCE
When output frequency has reached this percentage of reference, running feedback is set high.
P8.2 F
REQUENCY SUPERVISION FUNCTION
0: No supervision
1: Low limit
2: High limit
P8.3 F
REQUENCY SUPERVISION LIMIT
Threshold value.
P8.4 C
URRENT SUPERVISION LIMIT
Threshold value.
P8.5 P
ROCESS DISPLAY SOURCE
Monitor V3.9 can show a process value, proportional to a variable measured by the drive.
Source variables are:
0: output frequency (max: Fmax)
1: motor speed (max: Speed at Fmax)
2: motor torque (max: Tnom)
3: motor power (max: Pnom)
4: motor current (max: Inom)
P8.6 P
ROCESS DISPLAY DECIMAL DIGITS
Number of decimals shown on monitor V3.9 and also on parameter P8.7.
P8.7 P
ROCESS DISPLAY MAX VALUE
Value shown on V3.9 when source variable is at its maximum. Proportionality is kept if the
source overtakes the maximum.