EasyManuals Logo

Vacon 20 SERIES User Manual

Vacon 20 SERIES
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #44 background imageLoading...
Page #44 background image
vacon • 41 Parameter description
3
P4.4 ACCELERATION TIME 2
P4.5 D
ECELERATION TIME 2
P4.6 R
AMP 2 S SHAPE
Ramp 2 is available only in Automatic mode, and is activated through digital signal defined in
P5.11. Automatic activation based on output frequency is also available.
P4.7 T
HRESHOLD ACCELERATION TIME 2
P4.8 T
HRESHOLD DECELERATION TIME 2
If P4.7 is not 0, acceleration time 2 is activated when output frequency is higher than the value.
If P4.8 is not 0, deceleration time 2 is activated when output frequency is higher than the value.
P4.9 Q
UICK STOP DECELERATION TIME
Specific ramp time for quick stop. To see description of P2.5 for details about the function.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vacon 20 SERIES and is the answer not in the manual?

Vacon 20 SERIES Specifications

General IconGeneral
Output Voltage0 to Input Voltage
Storage Temperature-40°C to +70°C
DimensionsVaries by model
WeightVaries by model
Power Range0.25 kW to 18.5 kW
Voltage Range200 V to 480 V
Control MethodSensorless vector control
Protection ClassIP20
Ambient Temperature-10°C to +50°C
Communication OptionsModbus, CANopen
EMC FilterIntegrated
STO (Safe Torque Off)Yes
Input Voltage208-240 V, 380-480 V
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Overtemperature
Operating Temperature-10°C to +50°C
Humidity5% to 95% non-condensing