108
Step Description
Action
1
Make sure the EPU in the engine room is switched ON.
2
Reset the MCU by pushing the Reset button.
3
Turn the key switch of the MCU to Control Mode.
4
Wait for 1 minute and write down any alarm which comes up.
Acknowledge the alarm by pressing “ACK” and wait again for one minute.
(Inform VAF if any alarm comes up.)
5
Go through the configuration menu of the MCU.
6
Source for ship’s speed (GPS/Speed log). Set to: Ship’s log
7
Go through the setup menu of the MCU and write down the input.
8
Sample point. Write down
9
Total oil limit. Write down
10
Reset total oil. Set to: Yes
11
Discharge alarm. Set to: 30 l/NM
12
Speed indication. Set to: Auto
13
Flow rate indication. Set to: Auto
14
Oil type. Write down
15
Concentration alarm. Set to: 1000 ppm
16
Printing interval. Set to: 10 min
17
Oil concentration indication. Set to: Auto
18
Date and time.
19
Press the Flush key to go into flush mode.
20
Check if the pump is running now.
21
Wait until system comes in Idle mode.
22
Push the ? Key. Active alarms will be shown. Write down
23
After print out the MCU will go back to Idle mode.
24
Push the Stop key.
25
The system will go to Stand-by.
26
Turn the key switch to OFF.