EasyManua.ls Logo

Vaisala CL31 - Optical System Specifications; Performance Specifications; Environmental Conditions Specifications; Table 33 Optical System Specifications

Vaisala CL31
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
USER'S GUIDE____________________________________________________________________
132 _________________________________________________________________ M210482EN-D
Optical System Specifications
Table 33 Optical System Specifications
Property Description / Value
Optics System Focal Length 300 mm (11.8 in.)
Effective lens diameter 96 mm (3.8 in.)
Lens transmittance 96 % typical
Window transmittance 97 % typical, clean
Performance Specifications
Table 34 Performance Specifications
Property Description / Value
Measurement range 0 ... 7.5 km (0 ... 25 000 ft.)
Measurement resolution 10 m (33 ft) or 5 m (16 ft), selectable
Reporting resolution 5 m or 10 ft., units selectable
Reporting interval 2 ... 120 s, selectable
Measurement interval 2 s default (3 s in high-resolution mode)
Environmental Conditions Specifications
Table 35 Environmental Conditions Specifications
Property Description / Value
Temperature range -40 ... +60 °C (-55 ... +60 °C optional)
-40...+140 °F (-67...+140 °F optional)
Humidity 0 … 100 % RH
Wind to 50 m/s (110 kt)
Vibration Lloyds Register / IEC60068-2-6
5 - 13.2 Hz, ± 1.0 mm
13.2 - 100 Hz, ± 0.79 g

Table of Contents