Table 8 User Level Commands
Command Description
close Closes a user interface. Releases a port for message
transmission.
get diag contamination Prints diagnostic history of window contamination.
get diag angle Prints diagnostic history of inclinometer angle.
get diag battery Prints diagnostic history of battery voltage.
get diag int_temp Prints diagnostic history of internal temperature.
get diag l_power Prints diagnostic history of laser power.
get diag l_temp Prints diagnostic history of laser temperature.
get failure history Prints history of alarm and warning status.
get failure status Shows active alarms and warnings.
get params data_acq Prints data-acquisition related parameters.
get params factory Prints factory calibration values.
get params message Prints message related parameters.
get params port Prints serial port and modem parameters.
get sensors Prints data-acquisition values, tilt angles, and
humidity, if available.
get temperatures Displays temperatures.
get uptime Displays uptime clock.
get voltages Displays voltages.
name Displays device type, name, and ID.
open Opens a user interface.
reset Resets the ceilometer using the watchdog reset.
set control blower on Sets the window blower on.
set control blower off Sets the window blower off.
set control blower manual Sets manual control.
set control blower auto Sets automatic control.
set control inheater on Sets inheater on.
set control inheater off Sets inheater off.
set control inheater manual Sets manual control.
set control inheater auto Sets automatic control.
set control outheater on Sets outheater on.
set control outheater off Sets outheater off.
set data_port baud 115.2 k Data serial port speed.
set data_port baud 57.6 k Data serial port speed.
set data_port baud 38.4 k Data serial port speed.
set data_port baud 19.2 k Data serial port speed.
set data_port baud 9600 Data serial port speed.
set data_port baud 4800 Data serial port speed.
set data_port baud 2400 Data serial port speed.
set data_port baud 1200 Data serial port speed.
set data_port baud 300 Data serial port speed.
set data_port mode RS-232 Data serial port mode.
set data_port mode RS-485 Data serial port mode.
set data_port parity 7E1 Data serial port settings.
set data_port parity 7O1 Data serial port settings.
set data_port parity 7N2 Data serial port settings.
set data_port parity 8N1 Data serial port settings.
set defaults Restores the following default settings:
Operation mode: normal
Measurement mode: standard
Data acquisition autoadjustments: on
Blower control: auto
Inheater control: auto