Table 8  User Level Commands 
Command Description 
close  Closes a user interface. Releases a port for message 
transmission. 
get diag contamination  Prints diagnostic history of window contamination. 
get diag angle  Prints diagnostic history of inclinometer angle. 
get diag battery  Prints diagnostic history of battery voltage. 
get diag int_temp  Prints diagnostic history of internal temperature. 
get diag l_power  Prints diagnostic history of laser power. 
get diag l_temp  Prints diagnostic history of laser temperature. 
get failure history  Prints history of alarm and warning status. 
get failure status  Shows active alarms and warnings. 
get params data_acq  Prints data-acquisition related parameters. 
get params factory  Prints factory calibration values. 
get params message  Prints message related parameters. 
get params port  Prints serial port and modem parameters. 
get sensors  Prints data-acquisition values, tilt angles, and 
humidity, if available. 
get temperatures  Displays temperatures. 
get uptime  Displays uptime clock. 
get voltages  Displays voltages. 
name  Displays device type, name, and ID. 
open  Opens a user interface. 
reset Resets the ceilometer using the watchdog reset. 
set control blower on  Sets the window blower on. 
set control blower off  Sets the window blower off. 
set control blower manual  Sets manual control. 
set control blower auto  Sets automatic control. 
set control inheater on  Sets inheater on. 
set control inheater off  Sets inheater off. 
set control inheater manual  Sets manual control. 
set control inheater auto  Sets automatic control. 
set control outheater on  Sets outheater on. 
set control outheater off  Sets outheater off. 
set data_port baud 115.2 k  Data serial port speed. 
set data_port baud 57.6 k  Data serial port speed. 
set data_port baud 38.4 k  Data serial port speed. 
set data_port baud 19.2 k  Data serial port speed. 
set data_port baud 9600  Data serial port speed. 
set data_port baud 4800  Data serial port speed. 
set data_port baud 2400  Data serial port speed. 
set data_port baud 1200  Data serial port speed. 
set data_port baud 300  Data serial port speed. 
set data_port mode RS-232  Data serial port mode. 
set data_port mode RS-485  Data serial port mode. 
set data_port parity 7E1  Data serial port settings. 
set data_port parity 7O1  Data serial port settings. 
set data_port parity 7N2  Data serial port settings. 
set data_port parity 8N1  Data serial port settings. 
set defaults  Restores the following default settings: 
Operation mode: normal 
Measurement mode: standard 
Data acquisition autoadjustments: on 
Blower control: auto 
Inheater control: auto