EasyManua.ls Logo

Vaisala CL31 - CT12 K Digital Message No. 3

Vaisala CL31
142 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5 ________________________________________________________________ Operation
VAISALA_______________________________________________________________________ 77
Data values are presented for each 50 ft range gate. The height of the first
value in the line in thousands of feet. Two digits, a leading zero is
replaced by a space. Twenty 50 ft values per line starting with 0 (ft), next
line 1 000 (ft). 13 lines altogether. Last line (12 000 ft) has 10 values.
CT12K Digital Message No. 3
This message contains Status Line 1 identical to Message No. 2 (see
section CT12K Digital Message No. 2 on page 73) and one single range
gate data line indicating the presence or absence of backscatter in each
range gate.
An example of digital message No.3 is presented below:
10 04200 00150 ///// ///// 0000011010
0001FFF80000000000007A000......000
ON/OFF data is 1/0 accordingly. Other data is decimal or hexadecimal
numbers. The total length of the message is 112 characters. The printout
is 2 lines, the maximum width is 66 characters, of which 64 are visible.
The time for message transmission at 300 baud is 3.73 s.
Message Interpretation:
1ST LINE
Example:
where
= Start-of-Heading character
= Carriage Return + Line Feed
2ND LINE
The first line of the message is status line 1. Status line 1 of digital
message No.3 is identical to that of message No. 2 (see section CT12K
Digital Message No. 2 on page 73).