Chapter 5 ________________________________________________________________ Operation
VAISALA_______________________________________________________________________ 59
Command Description
Diagnostics intervals: 2 min
Power-save mode: disabled
Power-save sleep interval: 60 s
Message angle correction: on
Message transmission: periodic
Message transmission delay: 100 ms
Message height-offset: 0
Message interval: 2 s
Manual message: disabled
Message port: data
Message profile scale: 1.0
Message profile noise-h2: off
Message type: msg2_20x385
Message units: feet
Message VV limit ceiling: 6562 ft (2000 m)
Port timeout: 2 min
Unit ID: 0
set diag interval angle Sets diagnostic-data logging interval (min). 0
disables.
set diag interval battery Sets diagnostic-data logging interval (min). 0
disables.
set diag interval contam Sets diagnostic-data logging interval (min). 0
disables.
set diag interval int_temp Sets diagnostic-data logging interval (min). 0
disables.
set diag interval l_power Sets diagnostic-data logging interval (min). 0
disables.
set diag interval l_temp Sets diagnostic-data logging interval (min). 0
disables.
set diag clear Clears all diagnostic-data history.
set failure history clear Clears failure history.
set maint_port baud 115.2 k Maintenance serial port speed.
set maint_port baud 57.6 k Maintenance serial port speed.
set maint_port baud 38.4 k Maintenance serial port speed.
set maint_port baud 19.2 k Maintenance serial port speed.
set maint_port baud 9600 Maintenance serial port speed.
set maint_port baud 4800 Maintenance serial port speed.
set maint_port baud 2400 Maintenance serial port speed.
set maint_port baud 1200 Maintenance serial port speed.
set maint_port baud 300 Maintenance serial port speed.
set maint_port parity 7E1 Maintenance serial port settings.
set maint_port parity 7O1 Maintenance serial port settings.
set maint_port parity 7N2 Maintenance serial port settings.
set maint_port parity 8N1 Maintenance serial port settings.
set message transmission delay Sets request-based delivery response delay (ms).
set message transmission periodic Sets periodic message transmission.
set message transmission request Sets message request-based delivery.
set message interval 2 ... 120 Sets message delivery interval in seconds.
set message port data Delivers messages into data port.
set message port maintenance Delivers messages into maintenance port.
set message type msg1_10x770 Sets Msg1 with 10x770 profile.
set message type msg1_20x385 Sets Msg1 with 20x385 sample profile with 385
samples and 20 m resolution.
set message type msg1_5x1500 Sets Msg1 with 5x1500 profile.
set message type msg1_5x770 Sets Msg1 with 5x770 profile.