Chapter 5 ________________________________________________________________ Operation
VAISALA_______________________________________________________________________ 61
Command Description
service sw_update Updates the software.
set data_acq autoadj on Sets SW-control of data acquisition parameters.
set data_acq autoadj off Disables SW-control of data acquisition parameters.
set data_acq meas_mode standard Maximum range 7700 m, 10 m resolution, laser
pulse rate 10 kHz.
set data_acq meas_mode high_res Maximum range 7550 m, 5 m resolution, laser pulse
rate 8 kHz.
set data_acq power_save disable Disables power-save mode.
set data_acq power_save enable Enables power-save mode.
set data_acq power_save interval
30 ... 30000
Power-save interval in seconds. Default is 60.
set data_acq receiver gain low Sets receiver to low gain.
set data_acq receiver gain high Sets receiver to high gain.
set data_acq transmit length_of_p short Sets transmitter to short pulse.
set data_acq transmit length_of_p long Sets transmitter to long pulse.
set data_acq transmit inlaser 0 ... 4095 Sets control value for laser pulse.
set factory calibr_outlaser Starts automatic calibration of target outlaser.
set factory cross_talk Calibrates factory crosstalk.
set factory opt_sensit Sets optics sensitivity.
set factory outlaser 0 .. 2500 Sets target outlaser.
set factory receiver_type clr311 Sets receiver type to CLR311
set factory receiver_type clr321 Sets receiver type to CLR321
set factory win_clean Sets window clean status for window cond.
calibration.
set message angle_corr on Heights in messages are corrected for the tilt angle.
set message angle_corr off Heights in messages are not corrected for the tilt
angle.
set message height_offset <value> Sets height offset in current units.
(Range is -304 ... 304 m or -1000 ... 1000 ft.)
Positive values are added to and negative values
are subtracted from the measured height.
set message manual_msg <string> Sets a manual message. Empty string disables.
set message profile scale Scaling factor for range gate data (%).
set message profile noise_h2 on Range gates data is always range normalized, even
noise.
set message profile noise_h2 off Range gates data is range normalized, if backscatter
is contained.
set message units feet Reported heights unit is feet.
set message units meters Reported heights unit is meters.
set message vv_limit ceiling Sets vertical visibility ceiling limit (meters/feet). No
vertical visibility will be reported above this limit.
(Default: 2000 m).
set option humitter on Enables the humitter option.
set option humitter off Disables the humitter option.
set option sky_cond off Disables the sky condition option.
set option sky_cond on 0 .. 99999 Enables the sky condition option with an activation
code.