User’s Guide ______________________________________________________________________
124 _________________________________________________________________ M211840EN-C
12.5 = Transducer id 1 data (Supply voltage)
V = Transducer id 1 units (V, Supply voltage)
1 = Transducer id for Supply voltage
U = Transducer id 2 type (voltage)
3.460 = Transducer id 2 data (3.5V reference voltage)
V = Transducer id 2 units (V, 3.5V reference voltage)
2 = Transducer id for 3.5V reference voltage
G = Transducer id 4 type (generic)
HEL/___ = Transducer id 4 data (info field)
Transducer id 4 units (none, null)
4 = Transducer id for generic field
* Checksum delimiter
2D = Two-character CRC for the response.
<cr><lf> = Response terminator
1. See Chapter 8, Supervisor Message, Setting Fields for definitions of the
Heating voltage field.
Table 20 Transducer Table
Transducer Type Units Field Comments
Temperature C C = Celsius
F = Fahrenheit
Angular displacement
(wind direction)
A D = degrees
Wind speed S K = km/h, M = m/s, N = knots
S = mph, non-standardized
1
Pressure P B = bars, P = Pascal H = hPa, I = inHg, M = mmHg
Humidity H P = Percent
Accumulated
precipitation
V M = mm, I = in, H = hits non-standardized1
Time (duration) Z S = seconds non-standardized1
Intensity (flow rate) R M = mm/h, I = in/h, H = hits/h
for rainfall
M = hits/cm
2
h, I = hits/in
2
h, H
= hits/h for hails
non-standardized1
Voltage U V = volts (also 50 % duty cycle
for heating)
N = not in use, F = 50% duty
cycle for heating, W = full
power for heating
Generic G None (null)
P=Percent
1. Not specified in the NMEA 0183 Standard.