User’s Guide ______________________________________________________________________
160 _________________________________________________________________ M211840EN-C
Analog Output Signal for Wind
Direction Chanel
Analog interfaces setup default configuration:
Current output 4 ... 20 mA, offset 4 mA
4 mA = 0 degree
20 mA = 360 degree (0,044444 mA/°)
Error indication sets output to 2 mA
Analog interfaces setup, configuration 2:
Current output degree 0 ... 20 mA, offset 0 mA
0 uA = 0 degree
20 mA = 360 degree (0,055556 mA/°)
Error indication sets output to 22 mA
Enabling or Disabling Analog
Output
When changing the analog output setting, the setting is applied after the
transmitter reset. When analog output is in use, the serial port does not
work but the service connector does.