EasyManua.ls Logo

Vaisala WXT532 - Supervisor Data Message Request (aR5)

Vaisala WXT532
235 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7 ___________________________________________________ Retrieving Data Messages
VAISALA_______________________________________________________________________ 91
Example of the response (the parameter set is configurable):
0R1,Dn=236D,Dm=283D,Dx=031D,Sn=0.0M,Sm=1.0M,
Sx=2.2M<cr><lf>
For information on changing the parameters and units in the response
message, see Wind Sensor on page 127.
Pressure, Temperature and
Humidity Data Message (aR2)
This command requests a pressure, temperature, and humidity data
message.
Command format: aR2<cr><lf>
where
a = Device address
R1 = Wind message query command
Dn = Wind direction minimum (D = degrees)
Dm = Wind direction average (D = degrees)
Dx = Wind direction maximum (D = degrees)
Sn = Wind speed minimum (M = m/s)
Sm = Wind speed average (M = m/s)
Sx = Wind speed maximum (M = m/s)
<cr><lf> = Response terminator
where
a = Device address
R2 = Pressure, temperature and humidity message query
command
<cr><lf> = Command terminator

Table of Contents

Related product manuals