Chapter 11 ____________________________________________________ Technical Specifications
VAISALA______________________________________________________________________ 173
CHAPTER 11
TECHNICAL SPECIFICATIONS
This chapter provides the technical data of the WXT530 Series
transmitters.
Performance
- A naturally aspirated radiation shield is applied which can affect readings in calm wind.
Table 29 Barometric Pressure
Property Description/Value
Range 600 ... 1100 hPa
Accuracy (for sensor element) ±0.5 hPa at 0 ... +30 °C (+32 ... +86 °F)
±1 hPa at -52 ... +60 °C (-60 ... +140 °F)
Output resolution 0.1 hPa, 10 Pa, 0.001 bar, 0.1 mmHg,
0.01 inHg
Units available hPa, Pa, bar, mmHg, inHg
Table 30 Air Temperature
Property Description
Range -52...+6C (-60...+14F)
Accuracy (for sensor element)
at +20 °C (+68 °F)
±0.3 °C (0.17 °F)
Output resolution 0.1 °C (0.1 °F)
Units available °C, °F

Table of Contents

Related product manuals