User’s Guide ______________________________________________________________________
92 __________________________________________________________________ M211840EN-C
Example of the response (the parameter set is configurable):
0R2,Ta=23.6C,Ua=14.2P,Pa=1026.6H<cr><lf>
For information on changing the parameters and units in the response
message, see Pressure, Temperature, and Humidity Sensors on page
134.
Precipitation Data Message (aR3)
This command requests the precipitation data message.
Command format: aR3<cr><lf>
where
a = Device address
R2 = Pressure, temperature and humidity query command
Ta = Air temperature (C = °C)
Ua = Relative humidity (P = % RH)
Pa = Air pressure (H = hPa)
<cr><lf> = Response terminator
where
a = Device address
R3 = Precipitation message query command
<cr><lf> = Command terminator