3
At the login prompt, type admin and press Enter.
4
At the Password prompt, type the password that is assigned to the administrator
for this application. The default password is P@ssw0rd. The Main_Menu prompt
appears.
5
At the Main_Menu prompt, type support and press Enter. The Support prompt
appears.
6
At the Support prompt, type shutdown and press Enter.
7
Wait for the appliance to shut down gracefully. (About five minutes.)
8
Turn off the switches on the power supplies.
Preparing the appliance to install the additional
hardware
Best practices recommend removing the appliance from the rack to access the
inside of the chassis. Alternatively you can pull out the appliance on its rails. Be
sure that the appliance and rack are stable.
To prepare the NetBackup 5230 appliance for the installation of the hardware
1
Verify that the appliance is turned off. Refer to this section as needed.
See “Shutting down the appliance” on page 50.
2
Disconnect the AC power cords and peripheral cables as applicable.
3
Slide the NetBackup 5230 appliance forward on the rails to the full extension.
Caution: The unit weighs up to 65 lbs (29.5 kg). Make sure that sliding it forward
does not destabilize the rack.
Note: If it is necessary to remove the unit from the rack, place the unit on a
grounded, ESD protective surface.
4
Do the following to remove the chassis cover:
51Adding 3U16 storage shelves to an operational NetBackup 5230 Appliance
Preparing the appliance to install the additional hardware