Configuration Parameters D-7
Appendix D: Using the Configuration File
Edge 5000 Installation / Configuration Guide
VOIP timer_t1 Sets the lowest value, in milliseconds, for the retransmission of
SIP messages.
Valid values are 100 to 640.
Default is 250.
timer_t2 Sets the highest value, in milliseconds, for the retransmission of
SIP messages.
Valid values are 641 to 6400.
Default is 2000.
max_line_num Sets the number of flexible buttons allocated for SIP lines.
Valid values are:
IP-5000 phone — 1 to 24 or 1 to 36 (w/Exp. module)
Default is 2.
centralized_conference Enables use of a centralized conference server to process audio
for the conference.
Valid values are enable or disable
Default is enable.
conference_url Specifies the URI for the centralized conference server.
The valid value is a URI of less than 50 characters.
Default is the call server address.
blf Specifies use of the Broadsoft BLF for notifications of DSS line
status
Valid values are enable or disable
Default is enable.
blf_url Specifies the URI for the BLF server.
The valid value is a URI of less than 50 characters.
Default is the call server address.
de_register Enables de-registration of each line during a reboot prior to
re-registering.
Valid values are enable or disable
Default is enable.
stun_server Sets the STUN server IP address or FQDN
Valid value is an IP address or FQDN.
Default is blank.
Section Field Name Description