Figure 6.1 Replacing the Battery Pack
Item Description
1 Front cover
2 Battery door
3 Battery handle
4 Grasp handle and pull battery out.
6.2 Charging Batteries
The batteries are valve-regulated, non-spillable, lead acid batteries and should be kept charged to attain their design life. The
UPS charges the batteries continuously when it is connected to the utility input power.
If the UPS will be stored for a long time, we recommend connecting the UPS to input power for at least 24 hours every 4 to 6
months to ensure full recharge of the batteries.
6.3 Checking UPS Operation
NOTE: Operation check procedures may interrupt output power supplied to the connected load.
We recommend checking the UPS operation once every 6 months. Ensure that output power loss to the connected load will
not cause data loss or other errors before conducting the check.
1. Press the Enter button to check the indicators and display function, see Operation and Display Panel on page37.
2. Check for alarm or fault indicators on the operation/display panel.
3. Make sure that there are no audible or silenced alarms. Select the Log and look at the Current tab for alarm and
fault history, see Log Screen on page49.
4. Check the flow screen to ensure the UPS is operating in Normal mode. If the UPS is operating in Bypass mode,
contact Vertiv Technical Support.
5. Check the flow screen to see if batteries are discharging (operating in Battery mode) while utility power is
normal. If so, contact Vertiv Technical Support.
6 Maintenance Proprietary and Confidential ©2024 Vertiv Group Corp. 59
Vertiv™ Liebert® GXT5 UPS Installer/User Guide

Table of Contents

Other manuals for Vertiv LIEBERT GXT5 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vertiv LIEBERT GXT5 Series and is the answer not in the manual?

Vertiv LIEBERT GXT5 Series Specifications

General IconGeneral
ModelLIEBERT GXT5 Series
Product TypeUPS
TopologyDouble Conversion Online
DisplayLCD
Form FactorTower, Rackmount
Output Voltage200/208/220/230/240 VAC
Output Frequency50/60Hz ±0.1Hz (battery mode)
Typical Backup TimeVaries by model and load
Communication PortsUSB, RS-232
Operating Temperature0°C to 40°C (32°F to 104°F)
Relative Humidity0% to 95% (non-condensing)
DimensionsVaries by model
WeightVaries by model
CertificationsUL, cUL, CE, RoHS
Battery TypeValve Regulated Lead Acid (VRLA)