Installing the machine
4 Installing the machine
4.1 Checking the scope of delivery
M Unpack the machine and ensure you have received the
following items:
1 2
3 4 5 6
7 8 9 10
11 12 13
[1] 1 Machine K4 edition
[2] 1 spindle service set
[3] 1 power supply cord
[4] 1 USB cable
[5] 1 service unit for compressed air
[6] 1 hex key (3 mm) for the blank change
[7] 1 drill bit (2.8 mm) for tool positions
[8] 1 calibration set: 1 micrometer, 3 discs,
1 calibration tool
[9]
1 measuring pin
[10] 1 key for the emergency release of the working chamber
door
[11] 1 hose connection for the external air extraction system
[12] 1 pneumatic hose (0.5 m length)
[13] 7 tool magazine inserts (as spare parts)
Without illustrations:
This document
h Please keep the machine packaging for future transport.
4.2 Choosing the installation site
The installation site must meet the following criteria:
Firm and even surface, must carry the weight of the
machine
Ambient temperature (storage / transport): between
-20°C(-4°F)and60°C(140°F)
Ambient temperature (operation): between 10°C
(50°F)and32°C(90°F)
Relative air moisture maximum 80 %, non-condensing
Machine location must be dust-free
Alternating current source with 100 – 240 V and 50/60
Hz, max. 300 W
Compressed air supply that meets the requirements of
the machine (
chapter 4.4, page 13)
Sucientspaceatthesidesofthemachine
(
page 10)