Original Operating Instructions: K4 edition
Document version: E – 02/2020
Troubleshooting
8 Troubleshooting
DANGER
Danger to life due to improper troubleshooting
In case of improper troubleshooting, you may suer from
severe or deadly injuries caused by, for example, electric
shocks, axis and spindle movements, loose pneumatic com-
ponents and pneumatic hoses. In addition, your machine
ma
y get damaged.
h Do not remove the housing of the machine.
h Before you check or run pneumatic hoses, close the ex
-
ternal compressed air supply valve.
h Before you check or run electric cables or power con-
nectors, disconnect the machine from the electrical
sour
ce and prevent it from being r
estarted.
h Do not perform any troubleshooting while the machine
is operating.
h Wear safety gloves throughout the troubleshooting pro
-
cess.
h If you are unsure of how to perform certain steps during
troubleshooting or cannot solve the problems, abort the
troubleshooting and contact customer service.
Additional symbols in this chapter
a
Problem / question
Ø
Solution / answer
Frequently Asked Questions (FAQ)
a
The suction hose of my suction device does not t
into the opening for the air extraction system of the
Machine.
Ø
Is the suction hose equipped with a hose connection?
M1. Unscrew the hose connection from the suction hose.
M2. Try to insert the suction hose into the opening for the
air extraction system.
M3. Ifthesuctionhosestilldoesnott,screwtheprovided
hose connection onto the suction hose and try to insert
it into the opening for the extraction system.
Chapter 4.5.3, page 15
Ø
Did the suction hose come without a hose connec-
tion?
M1.
Screw the provided hose connection onto the suction
hose.
M2. Try to insert the suction hose into the opening for the
air extraction system.
Chapter 4.5.3, page 15
a
I cannot open the working chamber door.
Ø
Is the machine operating? While the axes are moving,
the working chamber door stays locked.
M Waituntilthemachinehasnished.
b
Without electricity, the working chamber door remains
locked.
Ø
Has a power failure occurred at the installation site of
the machine?
M Depending on the duration of the power failure, restart
the machine or use the key for the emergency release.
Chapter 5.7.4, page 21
Ø
Is electricity available at the installation site of the
machine?
M1. Connect the machine to the electrical source and switch
it on via the main power switch.
M2. If the working chamber lighting does not illuminate,
check if the power cable is properly seated in the ma
-
chine and is connected to the power source.
M3.
Tryconnectingthemachinetoadierentsocket.
Chapter 3.2, page 8
a
I have installed all components, started DentalCNC
but the machine does not reference.
Ø
Is the working chamber door open? The machine does
not reference with the working chamber door open.
M Close the working chamber door.
Ø
Is the USB cable connected properly?
M Check if the USB cable is properly seated in the con-
nector and is undamaged. If possible, use the provided
cable.
Ø
Is the correct port specied in DentalCNC? Without
the correct port, the application will not establish a
connection with the machine.
S1. Start DentalCNC.
S2. Try to have the application determine the correct port
in the application settings.
Chapter 4.7, page 16
S3. If the application cannot determine the correct port,
enter the port manually.
Documentation for the manufacturing software