Remote Commands
SCPI Commands Command Tables
MAP-200 Optical Switch mOSW-C1 Installation and User Guide Standard
June 2016 Document Number 22112369-120 R000 Page 47
Common Commands
The following table lists common commands of the mOSW-C1 cassette
:ERRor?
<err id>,
<description>
Extracts the first error code of the error
queue
:BUSY? <state> Query the busy state of the card
:RESet Reset the cassette to its default state.
:TEST? <test result> Perform a self test.
:CONFig?
<dev> <type>
<maxin>…
Query configuration of all devices
:INFOrmation?
<serial> <part>
<firmware rev>…
Query card information
:LOCK
<state>,
<owner>, <ipid>
Lock the specified application for the
exclusive use of the owner.
:LOCK?
<state>,<owner>,
<ipid>
Query the lock status of an application.
:RELEase Release the lock of an application
:INFOrmation? <dev> <dev info> Query the device description
:SLOT? <register> Query fault register
:DEVice? <dev> <register> Query fault register of device
:DEVice? <dev> <register> Query status register of device
:RESet <dev> Reset status register of devicer