Remote Commands
Common Application Commands
MAP-200 Optical Switch mOSW-C1 Installation and User Guide Standard
June 2016 Document Number 22112369-120 R000 Page 88
:ROUTe:WAVelength?
Description
Query wavelength value of the specified device. The command only works for the switch
device that has optical power monitor
Input Format
:ROUTe:WAVelength? <D>
Output Format
<wavelength>
Parameter
Type
Value
Wavelength Float
min wavelength max
wavelength
Default
0
Example
The following example queries the wavelength value of the switch device 1.
Terminal Input:
:ROUT:WAV? 1
Terminal Response:
1550
The above response indicates the wavelength value of the switch device 1 is 1550nm