VE.Bus Inverter/charger
Devices
Only VE.Bus MultiPlus/Quattro. Phoenix Inverter VE.Bus is also exported by this service, but then with number of AC inputs set to
0. The DSA is set to 66 (Inverter #1).
Instances
• Inverter: default instance 1, configurable from 1…13
• Charger: default instance 1, configurable from 1…13
• Line #1: default instance 0 (L1), configurable from 0…1
• Line #2: default instance 1 (L2), configurable from 0…1
• DC source: default instance 1, configurable from 1…250
Status
DGN DGN# Value
INVERTER_AC_STATUS_1 0x1FFD7 L1 AC out voltage, current, frequency
L2 AC out voltage, current, frequency
L2 data is not sent when not configured
INVERTER_STATUS 0x1FFD4 Inverter status
CHARGER_AC_STATUS_1 0x1FFCA L1 AC input voltage, current, frequency
L2 AC input voltage, current, frequency
L2 data is not sent when not configured
CHARGER_AC_STATUS_2 0x1FFC9 Input current limit
CHARGER_STATUS 0x1FFC7 Charger state
CHARGER_STATUS_2 0x1FEA3 DC voltage, current
CHARGER_CONFIGURATION_STATUS 0x1FFC6 Maximum charge current
CHARGER_CONFIGURATION_STATUS_2 0x1FF96 Input current limit,
Maximum charge current (%)
DC_SOURCE_STATUS_1 0x1FFFD DC voltage, current
Fixed priority of 100 (inverter/charger)
Commands
DGN DGN# Value
INVERTER_COMMAND
1)
0x1FFD3 Inverter enable/disable
CHARGER_COMMAND
1)
0x1FFC5 Charger enable/disable
CHARGER_CONFIGURATION_COMMAND 0x1FFC4 Maximum charge current Note: this is a volatile setting
and resets to the value the unit was configured with
after a restart of the inverter/charger.
CHARGER_CONFIGURATION_COMMAND_2 0x1FF95 Charger input current limit
1)
From RV-C you can control the charger and inverter part separately. These two on/off values are then combined into a
single switch value (as seen on the VE.Bus page in the GX user interface, see top most item in below screenshot). If the
inverter/charger is On, switching the charger off will result in Inverter only. Switching the inverter off will result in Charger only
(when shore power is connected).
Color Control GX Manual
Page 117 Appendix