To view NMEA 2000 devices on the MFD, go to Settings > Initial Setup > Data Aquisition > Sensor List. Here you can view basic
information and change Device instances and custom names.
13.6.7. Generic and supported PGNs
The following Victron related PGNs are supported:
PGN Description
127505 Fluid level (tanks)
127506 DC Detailed Status (State-of-charge, Time-to-go)
1)
127508 Battery Status (limited support); Voltage, Current
(1, 2)
1)
The tested Furuno MFD firmware supports a maximum of 4 batteries, no more
2)
Due to a bug in the MFD firmware, a negative battery current (ie. when discharging) is shown as --- (three dashes)