5.7.4. Wiring Example
The example below shows an overview of the recommended wiring based on an installation with a Lynx Smart BMS, Lynx
Distributors and a Cerbo GX.
The correct placement of the alternator shunt (not to be confused with the shunt of the BMV or SmartShunt) is important here for
the correct connection of the current sense wire.
For complete wiring between the WS500 and alternator, see the WS500 and the alternator manual.
Temperature sense
Alternator ATC
Shunt
Current sense
Lynx Smart BMS and Lynx Distributors
Cerbo GX
Alternator
WS500
Alternator
Color Control GX Manual