3-74 BA 50Z3/6003 en – Edition 4.3 * * 5003b330.fm
Operation
Protective FOPS structure/small screen – category I (option)
Danger!
Danger of crushing! Falling objects.
Causes severe injury or death.
Install a protective FOPS structure in areas with danger of falling objects.
Machine operation is prohibited without a protective FOPS structure.
Notice!
The protective FOPS structure corresponds to category I according to ISO
10262:1998.
The operator must ensure that the danger situation is evaluated and that the
national regulations are observed.
The operator must ensure that only work is performed that does not require any
higher protection.
Accidents cannot be fully avoided despite equipping a machine with protective
structures.
Installing
1 Stop and park the machine. Stop the engine.
2 A minimum 2 persons are required for installing/removing.
3 Tighten screws A (M10) and lock nuts on the left and right to 45 Nm (33 ft.lbs.).
4 Tighten screws B (M12) and lock nuts on the left and right to 87 Nm (64 ft.lbs.).
Fig. 154: Protective FOPS structure category I (symbolic
representation)
Fig. 155: Protective FOPS structure category I (assembly)