46
NESPRAY PLUS
3.6 TECHNICAL DATA 3.7 TRANSPORTATION
Push or pull the unit
Loosen the clamping rings (Item 1) at the shaft by turning
them to the left. Pull the shaft out to the desired length and
tighten the clamping rings again by turning them by hand to
the right.
1
Heating hose drum
Roll up the high-pressure hose and x to the hose guide park
tting. Seal connection hose with protective cap (2), so that
no material can escape. Coil connecting hose over the cable
holder. Roll up the mains connection cable onto the cable
holder.
Pull the locking pins (Item 1) on both sides of shaft. The lock-
ing pins can be arrested by a small turn (left or right). Pull the
shaft out and deblock the locking pins. A light pull or push will
help to lock the pins well.
Transportation in vehicle
Secure the unit and heating hose drum separately in the vehi-
cle by means of suitable fasteners.
DESCRIPTION OF UNIT
Voltage : 230 V AC, 50 Hz
Fuses : 16 A time-lag
Voltage at
multifunction switch : 24 V
Voltage at the
heating hose drum : 230 V
Unit connecting line : 6 m long, 3 x 1.5 mm²
Max. current consumption
hose heating : 5.2 A
Degree of protection : IP 54
Acceptance capacity : 2.6 kW
Max. operating pressure : 20 MPa (200 bar)
Max. volume ow : 3.5 l/min
Volume ow at 12 MPa
(120 bar) with water : 3.0 l/min
Heating of the
coating material to : 40 °C (standard)
i
Cold coating substance will result in a
longer warm-up phase.
Max. temperature of the
coating material : 43 °C
Max. nozzle size *: D319
Max. viscosity : 25.000 mPas
Empty weight pump : 44 kg
Empty weight
heating hose drum : 16.8 kg
Hydraulic oil lling
quantity : 0.9 liter
Max. tire pressure : 0.2 MPa (2 bar)
Max. sound pressure level: 74 dB (A)**
* based on surrounding and material temperature of 20°C.
During intervallic operation (gun opened/closed) bigger
nozzles can be used.
**Place of measurement: 1 m distance from unit and
1.60 m above oor, 12 Mpa (120 bar) operating pressure,
reverberant oor