103
VERSION 10/2018 ORDER NUMBER DOC 2339321
.
9.2.10.3 HIGHPRESSURE FILTER, 530 BAR
1.
Flush the pump and high-pressure lter in accordance with
Chapter 5.17 and with pump's operating manual. Flush using the
gun so that the ushing agent ows through the lter cartridge (F).
Maximize the ow (remove the nozzle, open the dosing valve if
necessary).
Filter
identication
Mobilux® EP2 *
Anti-seize paste*
53MPa
530bar
7687psi
Filter installation position
Turned over
Loctite® 542 *
Loctite® 542 *
12
11
10
7
3
5
B_06836
1
21
2
2. Empty the pump in a controlled manner in accordance with
Chapter 5.17 and the pump's operating manual.
3. Place the grounded collection tank under the high-pressure lter.
4. Open ball valve (J).
5. Loosen union nut (A) with a size 70 wrench.
6. Unscrew the union nut (A) and lift slightly so that it does not get
dirty in the next step.
7. Remove the lter housing (B) with the union nut (A). The cone
spring (E) remains in the lter housing (B). If the O-ring (D) is not
damaged, it remains on the lter housing (B).
8. Remove the lter cartridge (F) and lter socket (G) from the lter
housing (B).
9. Clean all parts:
–Place the lter cartridge (F) and lter socket (G) in solvent.
Clean using brush.
–Fill the lter housing (B) approx. 1/3 full with solvent.
Close, wearing gloves, and shake well.
–Clean the distribution housing (H) using a brush.
10. If necessary, replace the O-ring (D) and/or lter cartridge (F).
For order no., see spare parts catalog.
11. Assemble all parts in reverse order. While doing so:
–Coat the thread of the distribution housing (H) with anti-seize
paste*.
–Coat O-ring (D) and pressure ring (C) with Mobilux® EP2 *.
–Observe the installation position of the lter cartridge (F):
Push the closed end with the lter identication ahead into
the lter housing (B).
–Make sure that the cone spring (E) is in the lter housing
(note the installation position). Press on the cone spring after
inserting the lter cartridge (F) and lter socket (G);
the spring action must be noticeable.
–Tighten the union nut (A) by hand.
12. Close ball valve (J).
13. Clean the spray gun's product lter in accordance with the spray
gun's operating manual.
14.
Fill pump in accordance with Chapter 5.17 and the pump's
operating manual.
* For order no., see spare parts catalog.