28
VERSION 10/2018 ORDER NUMBER DOC 2339321
.
5.5.3 CONTROL UNITS WITH MAINS POWER SUPPLY CABLE
Unit
TwinControl control units with cable
connection
Input voltage
85–260
Input power
maximum 40
Input frequency
47-440
Permissible ambient temperature range
+5 < Ta < +40
+41 < Ta < +104
Protection class
Compressed air quality: free from oil and water
Quality standard 7.5.4 according to ISO 8573.1, 2010
7: Particle concentration 5–10mg/m³
5: Humidity: pressure dew point ≤ +7 °C
4: Oil content ≤ 5mg/m
5.5.4 ENTIRE SYSTEM
Working areas Unit Limits
Inlet air pressure
0.6–0.8
6–8
87–116
Maximum permissible number of strokes by
pumps in two-component operation
/min. 30
Maximum recommended strokes per minute of
pumps in 2K operation
/min. 20
Maximum product pressure levels
see Chapter 5.5.5
Product pH value
without acidic
hardeners
3.5–9
System for acidic hardeners:
Check products for compatibility (see Chapter 5.5.1)
Product temperature
+5 ... +60; +41 ... +140
Ambient temperature
Operation
+5 ... +40; +41 ... +104
Assembly
0 ... +40; +32 ... +104
Storage
-20 ... +60; -4 ... +140
Relative humidity 10–95% (without condensation)
Minimum ow rate
The minimum ow rate depends on the pump size, mixing ratio, static mixer and setting
for pressure and hardener valve stroke. Tests are required for volumes of less than 1 stroke
a minute (of A or B).
WARNING
Exhaust air containing oil!
Risk of poisoning if inhaled.
Provide compressed air free from oil and water.