75
VERSION 10/2018 ORDER NUMBER DOC 2339321
.
7.6.2 FLUSHING PROGRAMS
Flushing program mode
The ushing steps can be dened in the mode shown under
parameters F1 to F20.
B
A
SET
TwinControl
B
B
A
A
B_02744
Enter ushing program
– Press [SET] during program step F1 (to F20). A appears on the left to enter the action.
Use [+] or [-] button to select the value. For input values, see description of action in
Table 2.
– Press [SET].
– Enter the amount using the [+] or [-] button.
– Press [SET].
– Enter the measuring unit cc (= ml) or sec using the [+] or [-] button.
– Press [SET] (the measuring unit displayed is saved).
– The [+] or [-] button takes you to the next program step (F2 or Fx).
Table 1: ushing steps
Step F Actions Quantity Unit
*
*
Table 2: actions
Action Description of action
0 No activity
1 Product A
2 Product B
3 Flushing A
4 Flushing B
5 Wait time
Table 3: repetitions
Step F Step Description
F31 ** 3-20 Start repetition
F32 ** 3-20 End repetition
F33 1-200 Number of repetitions
** F31 must be smaller than F32.
* With repeated ushing (2 instances of ushing one after another), ushing steps
"F1" and "F2" are only performed the rst time. During the second ushing cycle, the
ushing program starts from step "F3".