EasyManua.ls Logo

WAGNER TwinControl - REPLACING FLUSHING AGENT WITH WORKING MEDIA

WAGNER TwinControl
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
60
VERSION 10/2018 ORDER NUMBER DOC 2339321
.
6.6.3 REPLACING FLUSHING AGENT WITH WORKING MEDIA
NOTICE
Interchange of the two components A and B!
Device damage due to hardened product.
Label device components and paint tank so that the components A and B are not
mixed up.
Prerequisites
At the start, all pumps should be lled with ushing agent just as after basic ushing
6.6.2).
Do not insert the nozzle into the gun yet. Gun secured.
Operating manuals for the aected components must be read and understood.
Process
1. Visual check: personal safety equipment, grounding and all devices ready to use.
2. Connect compressed air supply. Switch the system on.
3. Place the suction hoses of the three pumps in the respective grounded metal tanks:
ushing agent for the ushing pumps
master product for pump A
hardener product for pump B
4. Place grounded metal tanks for return product under the return tubes of pumps A
and B.
5. Set a low pressure (approx. 0.05 MPa; 0.5 bar; 7 psi) on the pressure regulators for the
three pumps.
6. Select "Work" in main menu.
7. Filling pump A:
7.1. Open return valve of pump A.
7.2. Slowly open ball valve of pump A.
7.3. Close the ball valve of pump A again as soon as pure working product comes out.
7.4 Close the return valve of pump A again.
7.5. In sub-menu, select component "A"
A
and press [Start].
7.6. Point the spray gun (preferably without nozzle) into the grounded metal tank
for return product and open carefully.
7.7. Slowly open ball valve of pump A.
7.8. Close the ball valve of pump A again as soon as pure working product without
air inclusions comes out.
7.9. Close and secure the spray gun.