80
VERSION 10/2018 ORDER NUMBER DOC 2339321
.
7.6.5 "BATCH MODE" FILLING MODE
The Batch Mode setting allows a recurring and pre-dened ow rate to be discharged via
the gun or via an external valve.
Batch Mode setting
Via password level 4 where pos. "P137" P137 = 1.
Other settings for the Batch quantity to be displayed:
Parameter pos. "P120" and "P121" must be set to one of the following values:
(job sum) or
(MR and JS in turn) or
(P and JS in turn) or
(MR and JS and P in turn).
Access for changing the Batch quantity
1.) Via password level 2 or
2.) Via parameter pos. "P142" P142 = 1 (no password protection for MR and Batch quantity).
Changing the Batch quantity
"Total" illuminated display must be ashing.
Press [Set] -> the current set value is displayed.
Use the [+] or [-] button to select the set value.
Use [SET] to save the new set value.
B
A
SET
TwinControl
B
B
A
A
B_02744
Operation
Press [Start].
Note:
If lling has not yet taken place, it is undertaken automatically.
Filling complete -> System at Stop.
Press [Start] again. The system is running and shifts to Stop when the target quantity is reached.
The operating cycle can be repeated any number of times.