EasyManua.ls Logo

WAGNER TwinControl - LIST OF SERVICE FUNCTIONS

WAGNER TwinControl
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
43
VERSION 10/2018 ORDER NUMBER DOC 2339321
.
5.10 LIST OF SERVICE FUNCTIONS
Software version V 4.0x / 4.1x / 4.2x
Unit Description
Filling
AB
Mixed product in the hose Adjustable
A
Volume A product from product valve to mixing block Adjustable
B
Volume B product from product valve to mixing block Adjustable
Flushing recipes
F1 1 or 2 Denition (0=not used; 1=A product; 2=B product) Adjustable
up to 0-9999.9 Quantity Adjustable
F20 cc/sec Measuring unit (0=cc; 1=sec) Adjustable
F31
Starting step for repetition Adjustable
F32
Final step for repetition Adjustable
F33
Number of repetitions Adjustable
System parameter
P0
Q Control Adjustable
P1
Actual value for Q Control Display
P2
Mixing tolerance Adjustable
P3
Actual value for mixing tolerance Display
P4
Actual value for position of stroke sensor A Display
P5
Actual value for position of stroke sensor B Display
P6 min-1 Turbine frequency in revolutions per min (set value 38000 to 45000) Display
P7 Pot life reset
P100 0 or 1 Password (0 = no, 1 = yes) for level 1 Adjustable
P101 Current software version Display
P102
/min. Running dry protection, pump A Adjustable
P103
/min. Running dry protection, pump B Adjustable
P104
/min. Max. number of double strokes – pump A where not hidden Adjustable
P105
/min. Max. number of double strokes – pump B where not hidden Adjustable
P106 min Pot life post-alarm Adjustable
P107 % of stroke Tolerance limit A for reversal point Adjustable
P108
Actual value reversal point stroke sensor A below Adjustable
P109
Actual value reversal point stroke sensor A above Adjustable
P110 % of stroke Tolerance limit B for reversal point Adjustable
P111
Actual value reversal point stroke sensor B below Adjustable
P112
Actual value reversal point stroke sensor B above Adjustable
P113
Measuring unit (0 = liters, 1 = US gallons, 2 = British gallons,
3 = conversion factor, can be set)
Adjustable
P114 0 or 1 Gun ush box (0 = no, 1 = yes) Adjustable
P115 0 or 1 Manual leak inspection (0 = no, 1 = yes) Adjustable
P116 mm/min Leak warning limit A Adjustable
P117 mm/min Leak error limit A Adjustable
P118 mm/min Leak warning limit B Adjustable
P119 mm/min Leak error limit B Adjustable

Table of Contents

Other manuals for WAGNER TwinControl

Related product manuals