Unit Description
P120
Front display in mixing mode and/or if gun is closed: 0 = mixing ratio (MR);
1 = ow rate or pot life (F_P); 2 = job sum (JS); 3 = MR and F_P in turn;
4 = MR and JS in turn; 5 = F_P and JS in turn; 6 = MR and F_P and JS
in turn.
Adjustable
P121
Front display if [Stop] has been pressed: 0 = mixing ratio (MR);
1 = pot life only (P); 2 = job sum (JS); 3 = MR and P in turn;
4 = MR and JS in turn; 5 = P and JS in turn; 6 = MR and P and JS in turn.
Adjustable
P122 0 or 1 Filling function with cycles of A (0 = o, 1 = on) Adjustable
P123 sec 0.0–10.0s cycle duration of lling function Adjustable
P124
0-100% of the cycle duration A-valve should be open Adjustable
P125
For 0-100% of the lling quantity, lling function should be on Adjustable
P126 0 or 1 Feed sequence (0 = AB, 1 = BA) Adjustable
P127
Password for level 1 Adjustable
P128
Password for level 2 Adjustable
P129
Password for level 3 Adjustable
P130
Password for level 4 Adjustable
P131 min Time delay for alarm no. 18 ush program is not running (1-10 min) Adjustable
P132
1 = Save customer settings; 2 = Load customer settings;
3 = Load factory settings (only displayed in stop mode)
Adjustable
P133
/min. Maximum double strokes of ushing pump A per min. Adjustable
P134
/min. Maximum double strokes of ushing pump B per min. Adjustable
P135
Number of A-cycles* 1000 for service message Adjustable
P136
Number of B-valve cycles* 1000 for service message Adjustable
P137 0 or 1 0 = batch mode o; 1 = batch mode on Adjustable
P138 0 or 1 Batch mode start via external signal (0 o, 1 = on) Adjustable
P139 0 or 1 0 = normal start, 1 = If start is pressed for more than 2 sec,
separate lling of A and B will not be undertaken.
Adjustable
P140 0 or 1 0 = emergency ushing o; 1 = emergency ushing on Adjustable
P141 0 or 1 0 = No ushing after error message; 1 = Flushing after error message Adjustable
P142 0 or 1 0 = Password for mixing ratio and batch mode quantity ;
1 = No password for MR and batch mode quantity
Adjustable
P143 0 or 1 0 = ow monitoring o; 1 = ow monitoring on Adjustable
P144
cc/min. Minimum ow Adjustable
P145
cc/min. Maximum ow Adjustable
P146
Delay time until alarm, when ow is over the limit Adjustable
P147 0 or 1 Calibration of the components A and B with predened quantity Adjustable
P148
cc/min. Calibration quantity for component A Adjustable
P149
cc/min. Calibration quantity for component B Adjustable