74
VERSION 10/2018 ORDER NUMBER DOC 2339321
.
7.6.1 CALIBRATION
(Password entry required for P100)
Calibrate A
[Start] -> Open gun -> With spray pressure, pump out around
5double strokes into measuring cup ->Gun closed -> [SET] ->
Enter measurement in measuring cup in cm
3
-> [SET]
(Cancel with [Stop] button)
B
A
SET
TwinControl
B
B
A
A
B_02744
Calibrate B
[Start] -> Open gun -> With spray pressure, pump out around
5double strokes into measuring cup ->Gun closed -> [SET] ->
Enter measurement in measuring cup in cm
3
-> [SET]
(Cancel with [Stop] button)
B
A
SET
TwinControl
B
B
A
A
B_02744
Calibration Flushing A
Direct input in cm
3
/ of ushing pump
B
A
SET
TwinControl
B
B
A
A
B_02744
Calibrate ushing B
Direct input in cm
3
/ of ushing pump
B
A
SET
TwinControl
B
B
A
A
B_02744