102
VERSION 10/2018 ORDER NUMBER DOC 2339321
.
9.2.10 CLEANING OR REPLACING THE PRODUCT FILTER
9.2.10.1 ANGLED INLINE FILTER 530 BAR
1.
Flush the pump and inline lter in accordance with Chapter 5.17 with pump's operating manual.
Flush using the gun so that the ushing agent ows through the inline lter. Maximize the ow
(remove the nozzle, open the dosing valve if necessary).
2.
Empty the pump in a controlled manner in accordance with Chapter 5.17 and the pump's operating
manual.
3. Place the grounded collection tank under the inline
lter.
Flow direction
* For order no., see spare parts catalog.
53MPa
530bar
7687psi
B_07113
C*
B
D
E
A*
E
F*
4. Unscrew the lter by turning the handle (D).
5. Remove the lter insert (C).
6. If the inline lter has any leaks: Replace the seal (A).
7. Insert the new lter insert (C). Note the installation
position: closed end in direction of ow.
8. If necessary, coat the thread with anti-seize paste (F).
9. Assemble the turning handle (D), inlet housing (B)
and outlet housing (E) and tighten by turning the
handle.
10. Clean the spray gun's product lter in accordance
with the spray gun's operating manual.
11.
Fill pump in accordance with Chapter 5.17 and the
pump's operating manual.
9.2.10.2 STRAIGHT INLINE FILTER 270 BAR
1.
Flush the pump and inline lter in accordance with Chapter 5.17 and with pump's operating manual.
Flush using the gun so that the ushing agent ows through the inline lter. Maximize the ow
(remove the nozzle, open the dosing valve if necessary).
2.
Empty the pump in a controlled manner in accordance with Chapter 5.17 and the pump's operating
manual.
3. Place the grounded collection tank under the inline lter.
27MPa
270bar
3916psi
* For order no., see spare parts catalog.
Flow direction
B_05274
2
3
5
1
**
4. Unscrew the inlet housing (B) and outlet housing(E) with two
size 19 wrenches.
5. Remove the lter insert (C).
6. If the inline lter has any leaks: Replace the seal (A).
7. Insert the new lter insert (C). Note the installation position:
closed end in direction of ow.
8. If necessary, coat the thread with anti-seize paste (F).
9. Screw together the inlet housing (B) and outlet housing (E)
with two size 19 wrenches.
10. Clean the spray gun's product lter in accordance with the
spray gun's operating manual.
11.
Fill pump in accordance with Chapter 5.17 and the pump's
operating manual.