11 REPAIRS
11.1 REPAIR PERSONNEL
Repair work should be undertaken carefully by qualied and trained personnel. They should
be informed of specic hazards during their training.
The following hazards may arise during repair work:
risk to health from inhaling solvent vapors,
use of unsuitable tools and aids.
A skilled person must check to ensure that the device is in a reliable state after it is repaired.
11.2 REPAIR NOTES
WARNING
Incorrect maintenance/repair!
Danger to life and equipment damage.
Only a WAGNER service center or a suitably trained person may carry out repairs and
replace parts.
Use only WAGNER original spare parts and accessories.
Only repair and replace parts that are listed in the "Spare parts" chapter and that are
assigned to the unit.
Before all work on the device and in the event of work interruptions:
− Switch o the energy and compressed air supply.
− Relieve pressure from spray guns, high-pressure hoses and all devices.
− Secure spray guns against actuation.
− Disconnect the control unit from the mains.
Observe the operating and service manual for all work.
Before Repair Work
Flush and clean the system. Chapter 9.1.4
Switch o the system. Chapter 8.6
After Repair Work
Carry out safety checks in accordance with Chapter 9.2.3.
Put the system into operation and check for leaks as described in Chapter 6.6.
Have the system checked for safe condition by an authorized person.