67
VERSION 10/2018 ORDER NUMBER DOC 2339321
.
[Stop] button
Device status Function of [Stop] button
Program running
Terminates active program. Resets all valves to original
status.
Program not running Returns to base position
Setting input [SET] Terminates input without saving
Alarm
Acknowledges alarm Fault rectication (Chapter 10)
Alarm
If there is a malfunction, the systems stops and the alarm display lights up. An error code
appears on the display.
Acknowledge with [Stop] button
Fault rectication in accordance with Chapter 10
Pot life
– Pot life display lights up
Pot life running.
– Pot life display ashing
Display shows the remaining pot life.
Display in the display unit
–
When working in accordance with system parameter P120 (see Chapter5.10).
–
After pressing [Stop] button in accordance with system parameter P121
(see Chapter5.10).
7.3.1 ENTERING NUMBERS SET
Changing and saving numbers
To change numbers
[SET], [+] (higher) or [-] (lower) Terminate data input [Stop] button
To save numbers
[SET] Into main menu 2x [Stop] button
If the indication "OFF" appears after making an entry in
the display, then the input authorization must be enabled.
B
A
SET
TwinControl
B
B
A
A
B_02744