25
VERSION 10/2018 ORDER NUMBER DOC 2339321
.
5.4 INCLUDED ITEMS
TwinControl systems consist of the following:
– pneumatic pump with stroke measurement for the A-component
– pneumatic pump with stroke measurement for the B-component
– pneumatic pump for ushing agent (versions without also possible)
– control unit (turbine or cable connection)
– frame or trolley or wall mount (wall mount not with PC)
– static mixing unit (only with internal mixer)
– diverse product valves
The system's scope of delivery also includes:
Description Order no.
Separating agent 250 ml; 250 cc 9992504
CE Declaration of Conformity
See Chapter 15
Operating manual, in German 2339287
Operating manual in the local language
See Chapter 1.3
TwinControl compact disc (CD, see Chapter 1.4) 2339342
Instruction sheet – transportation 2305117
Supplement for TwinControl with password protection 2304064
The delivery note shows the exact scope of delivery.
Accessories: see Chapter 13.
5.5 TECHNICAL DATA
5.5.1 MATERIALS OF PAINTWETTED PARTS
Materials in direct contact with the products
TwinControl (without pumps) Stainless steel, FEP, HM, PA, PE, POM, PTFE
Pumps
See pump operating manuals
(for order no., see Chapter1.3.1)
TwinControl systems for acidic hardeners:
– from B pump (input) to mixing head valve (output) 1.4404, 1.4408, 1.4571, FEP, HM, PE, PTFE
– Mixing tube, additional 1.4301
FEP = Fluorine elastomer
HM = Carbide
PA = Polyamide
PE = polyethylene
POM = Polyoxymethylene
PTFE = Polytetrauorethylene