55
VERSION 10/2018 ORDER NUMBER DOC 2339321
.
Cable cross-sections
TwinControl frame 4 mm; AWG 12
Paint tank / collection tank 6 mm; AWG 10
Conveyor 16 mm; AWG 6
Spray booth 16 mm; AWG 6
Spraying stand 16 mm; AWG 6
6.5.2 EXAMPLE OF GROUNDING SCHEME FOR TWINCONTROL WITH TURBINE
R max. < 1 MOhm
B_04532
A B
S
AB
AB
TwinControl
Ex zone 1 and 2
Legend Grounding cables Fluid hoses
3 TwinControl frame 5 Work piece 7 Floor, static dissipative 9 Remote control (option)
4 Paint tank 6 Conveyor 8 Flushing agent tank 10 Horn (option)
6.5.3 EXAMPLE OF GROUNDING SCHEME FOR TWINCONTROL WITH MAINS POWER CONNECTION
CABLE
R max. < 1 MOhm
B_04533
A B
S
AB
TwinControl
Non-Ex zone
Ex zone 1 and 2
Legend Grounding cables Fluid hoses
3 TwinControl frame 5 Work piece 7 Floor, static dissipative 9 Remote control (option)
4 Paint tank 6 Conveyor 8 Flushing agent tank 10 Horn (option)