66
VERSION 10/2018 ORDER NUMBER DOC 2339321
.
7.3 OPERATING THE CONTROL UNIT
For the meaning of all symbols/illuminated displays: see Chapter 5.8
B
A
SET
TwinControl
B
B
A
A
B_02744
Main menu
Sub-menu
Display
Setting buttons
[Flush] button
[Stop] button
[Start] button
Menu selection buttons
Alarm
Pot life
Tasks
Base position
When switched on, the control unit is in its base position. The three lamps "Work", "A" and "B"
are illuminated in the base position. Depending on system status, other lamps might light
up or ash.
Returning to base position
Press the [Stop] button once or twice.
Triggering action
1. Main menu selection (depending on personal authorization)
2. Sub-menu selection
3. [Start] or [Flush]
[Start] button
Main menu Sub-menu Function of the [Start] button
Tasks
A + B Start of work cycle
A A-valve opens
B B-valve opens
Flushing agent A A-ushing-valve opens
Flushing agent B
– With separate A and B ushing hoses
B
ushing valve opens
– If only one ush hose is connected directly to
mixer
[Start] button has no function
Circulation
operating mode
(option)
Circulation of A and B product