EasyManua.ls Logo

WAGNER TwinControl - GROUNDING OF COMPONENTS ON FRAME OR TROLLEY

WAGNER TwinControl
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
54
VERSION 10/2018 ORDER NUMBER DOC 2339321
.
6.5.1 GROUNDING OF COMPONENTS ON FRAME OR TROLLEY
B
A
7
11
12
22
21
24
25
5
3-
2-
1-
1
2
3
4
6
10
8-
8
9
Year of construction / Baujahr:
Serial No. controller:
Serie Nr. Steuerung:
Air pressure supply:
Luftdruckversorgung:
Prot. Class:
Schutzklasse:
Ambient temperature:
Temperatur Umge
0.6 - 0.8 MPa
6 - 8 bar
87 - 116 psi
+5 / +40 °C
CH 9450 Altstätten
TwinControl
Made in Switzerland
Type / Typ:
J. Wagner AG
Serial No unit.:
Serie Nr. Anlage:
+5°C < Ta < +40°C
II 2 G
Ex ia II B T4 X
ZELM 08 ATEX 0385 X
+5°C < Ta < +40°C
0102
3
6
2
1
4
B_04536
5
On the potential equalization
(signal ground)
Grounding connections
View of rear side of
system
Connect all grounding cables using a short and direct route.
from - to Line
1 A-pump on frame 4 mm; AWG 12
B_02805
Grounding connection point on frame.
View of operating side of system.
2 B-pump on frame 4 mm; AWG 12
3 Flushing pump on frame 4 mm; AWG 12
4 Control unit on frame 4 mm; AWG 12
5
2A switchbox (option) or reversing box
(ESTA remote control, option) on control
unit
4 mm; AWG 12
6 Frame to signal ground 4 mm; AWG 12