Malfunction Remedy
System does not start up Check air supply line connection.
Check the pressure value on the system's pressure gauge for the air supply
to the valves.
Check the voltage supply (Does the control panel light up?).
Check the selected valves.
Check the fuses.
System is in operation
(a pump is running), but
there is no product ow
Check the supply lines of the components as well as lters (clogging) and
suction tubes (leakage).
Check the component level in the supply tanks.
Check the viscosity of the components or the pressure loss.
System does not supply
any product, pumps do
not run
Check the mixing tube and feed hoses.
Check the guns and the gun lter.
Clean the lines by ushing or cleaning manually.
The 2K product does not
react correctly
Check the mixing ratio value.
Check the suction lines (leakage).
Check the stroke sensors by carrying out a calibration.
Check the dierential pressure between B and A (B approx. 5-10% higher
than A).
Check AIS function and stepping motor according to Chapter 7.6.3.
Without AIS: Optimize the switching behavior of the hardener dosing valve
in spraying mode (0.5-2 seconds) via the dierential pressure of B to A or via
the stroke setting of the valve.
Check the lacquer specications.
Flow rate is too low Check the mixing tube and feed hoses.
Check the guns and the gun lter.
Clean the lines by ushing or cleaning manually.
Increase the pressure of the supply pumps.
Lacquer loss from the
bleed bore of a product
valve
Replace the valve needle seal, check the valve needle and housing for damage
and if necessary, replace the entire valve.
Power failure over a
longer period of time
With external compressed air, manually open the ushing valve and distributor
valve (option).
The system supplies
product, but the spray
pattern is inadequate
Ensure that the supply pressures are constant.
The pressure of component B must be 10% higher than that of component A.
Increase the pressure of the supply pumps.
AirCoat: Set the atomizing air correctly.
Check the product lter with pumps and guns.
Replace gun nozzle with a more suitable nozzle (Airless and AirCoat).
Check the viscosity of the product and dilute it in accordance with the
lacquer manufacturer's instructions. If necessary correct the mixing ratio.
AirCoat: Ensure that only dry, clean atomizing air is used in the spray gun.
Flow rate is too high Replace gun nozzle (Airless and AirCoat).
Check the lines for leakage.
Set the opening of the gun needle correctly (air guns only).
Decrease the pressure of the supply pumps.