iPump User’s Manual
800009-01 Rev. A 50 wegener.com
equipment for proper function. Also check to determine if the program or file
is "blank".
Trouble using
browser
interface
If the iPump appears to be functioning normally with no alarm or warning con-
ditions, but you cannot use the web browser interface, first check that you are
using the correct IP address. (See “Web Browser Operations Startup” on
page 26.)
If the address is correct, but the interface still does not function, check your
computer’s IP settings and consult your network administrator for additional
help.
LED
Indicators
NOTE: Only one alarm or warning condition is displayed at a time on the
LCD. When multiple alarm or warning conditions exist, those conditions are
displayed in the order of importance. The most critical condition is displayed
first. Further alarms or warnings will be shown after the more critical item(s) is
cleared.
Table 9: LED Indicator Descriptions
Indicator Label Color and State Meaning
CARRIER
GREEN constant Receiver is tracking carrier.
GREEN slow blink Receiver is not tracking carrier.
RECORD
GREEN constant iPump is recording a program.
Off iPump is not recording.
DOWNLOAD
GREEN constant iPump is downloading a file via Compel.
Off iPump is not downloading.
LAN
GREEN constant Light network activity over the iPump’s LAN interface
GREEN slow blink Heavy network activity over the iPump’s LAN interface
Off iPump observed no packet transfers on the LAN interface during
the last 20 seconds.
COMPEL
GREEN constant iPump has received a COMPEL command within the last two
minutes.
GREEN fast blink iPump has been addressed by COMPEL within the last five sec-
onds.
GREEN slow blink iPump is in tracking mode, COMPEL is required, but no COM-
PEL command has been received within the last two minutes.
Off COMPEL is not required and not received within the last two
minutes; or, iPump is not in tracking mode.