上海维宏电子科技股份有限公司
Weihong Electronic Technology Co., Ltd.
Specialized, Concentrated, Focused - 33 -
Extended terminal board EX30A3 (175mm*118mm*56.5mm) is required in laser cutting, with wiring
diagram as shown in Fig. 2-24.
To connect Lambda 5S controller
+24V Power
Active High/Low
General Inputs
Blow (Oxygen)
Blow (Nitrogen)
Follow Control Switching
General Output 1
General Output 2
Red Light
Common
Common
Common
Common
Common
Common
+24V Single-ended Modulation Signal
+5V Single-ended Modulation Signal
To connect
laser
±5V Differential Modulation Signal
To connect
capacitive
sensor
Analog Output 1
Analog Output 2
Analog Output 3
1
2
4
3
Y00 Y01 Y02 Y03 Y04 Y05
COM
COM
COM
COM
COM
COM
Y00
Y01
Y02
Y03
Y04
Y05
COM
AV03
COM
AV02
COM
AV01
MOD(-)
MOD(+)
COM
MOD(24V)
COM
MOD(5V)
+3.3V
DEBUG
RS232
SENSOR
X00
X01
X02
X03
X04
X05
X06
X00
X01
X02
X03
X04
X05
X06
S
ACOM
AVI
COM
+24V
Fig. 2-24 Connection of EX30A3 according to laser cutting software
1) The outputs of extended terminal board EX30A3 are Darlington outputs, and their load current should be
≦0.4A.
2) Outputs Y00~Y05 should be connected to relays.