上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
74 / 97
Max Speed
• Unit: mm/min
• Range: [0, max speed]
• Default value: 10000
• Effective: Immediately
• Description: The maximum speed of X-axis, Y-axis and Z-axis.
Short Seg Spd Lmt
• Unit: -
• Range: Yes ; No
• Default value: Yes
• Effective: Immediately
• Description: Whether to enable speed limit for short segments.
Spd Lmt Length
• Unit: mm
• Range: [0, 100000]
• Default value: 0.5
• Effective: Immediately
• Description: When the length of a short segment is smaller than this parameter,
the speed to machine this short segment will be limited for machining effect.
Z Down Option
• Unit: -
• Range: 0; 1; 2
• Default value: 0
• Effective: Immediately
• Description: The downward cutting mode of Z-axis.
– 0: Not disposed.
– 1: Only Z axis.
– 2: X-axis, Y-axis and Z-axis synchronize.
Z Plunge Cut Spd
• Unit: mm/min
• Range: [0, Z Max Speed]
• Default value: 300
• Effective: Immediately
• Description: The downward cutting speed of Z-axis under G01 downward cut.