5 Service programs
Training manual Convotherm 4 64
5.1.2.3 Control values (adjustable parameters)
Control values (easyDial)
The control values allow read/write access to various function parameters. Basic appliance settings
can be made here and changes made to optimization values (e.g. burner speeds, ...)
Service no. Output Comments Range
c1
Trade-fair mode (dummy)
0 or 1 *
c2 easyDial update from USB to flash
memory
0 or 1 *
c3 SIB update from USB to flash
memory
0 or 1 *
c4 SIB Update from flash memory
(firmware download to SIB)
0 or 1 *
c5
Restart
0 or 1 *
c6
Factory presets
0 or 1 *
c7
Manual boiler rinse
0 or 1 *
c8
Unassigned
c9
Unassigned
c10
Unassigned
c11
Unassigned
c12
C12
0 - 9999
c13
C13
0 - 9999
c14
Unassigned
c15 Boiler preheat temperature
(Standby)
0 - 99
c16
Waste-water cooling temperature
80 - 99
c17 Low-temp steam bypass temper-
ature
80 - 99
c18
Auto-steam bypass temperature
80 - 99
c19
Quick-steam bypass temperature
80 - 99
c20 Low-temp combi-steam bypass
temperature
80 - 99
c21 Bypass temperature
Auto combi-steam
80 - 99
c22 Quick combi-steam bypass
temperature
80 - 99
c23
Supersteam bypass temperature
80 - 99
c24
Unassigned
c25
Restart after power cut
0 - 1440
c26
Restart with compensation
0 - 200
c27
Fan pulsed mode On
10 - 30
c28
Fan pulsed mode Off
60 - 300
c29
Fan on period
0 - 240
c30
Reduce fan speed
0 - 40
c31
Unassigned
c32
Water hardness
1 - 4
c33
Salination factor
100 - 5000