9 Servicing / Cleaning
Training manual Convotherm 4 137
9.3.1 Cleaning the dehumidifier valve
Component
Illustration Name
Dehumidifier valve
Tools required
Phillips screwdriver
Requirements
Check that the following requirements have been met:
The appliance has been disconnected from the power supply and protective measures taken to
ensure the power cannot be switched on again.
The left-hand side panel has been removed.
The dehumidifier valve has been removed.
Cleaning the dehumidifier valve
1.
Undo the four screws on the dehumidifier valve using a Phillips
screwdriver.
2.
Remove the top section of the dehumidifier valve.