5 Service programs
Training manual Convotherm 4 66
c52
ConvoVent mode
0 = off, only ON for specific events
1 = constant low speed, high speed for
specific events
2 = constant low speed only during cooking,
high speed for specific events (default
setting)
0 / 1 / 2*
c53
Preheat/cool down tolerance
0 - 300
c54 Multi/single-measure dispensing
for cleaning
1 = single dose, 0 = multi-dose
To switch between cleaning with connected
canisters and single-measure dispensing:
Press
0 or 1
c55
Volume control
5 - 100
c56
Signal length in seconds, 0 = continuous 3 - 600
c57 Volume control 2 for cooking when
door open
5 - 100
c58 Signal length 2 for cooking when
door open
in seconds, 0 = continuous 3 - 600
c59
Water filter (Filter Care)
0 = no water filter
1 = water filter connected
0 or 1 *
c60 Water filter (Filter Care)
NO/NC contact
0 = water-filter NO contact
1 = water-filter NC contact
0 or 1 *
* 0 = Off
1 = On