4. For the Service Technician
Operating time of suction turbine
Factory setting: 80 sec.
Einstellbereich: 50 – 120 sec.
Fig. 61
Maximum value of
set temperature
Actual value
75 °C
min. 60 °C
max. 75 °C
Save Back +
Fig. 62
Set temperature ext.
heating requirement
Actual value 70 °C
min. 35 °C
max. 75 °C
Save Back +
Fig. 63
Type of pellet feed system
without feed system
Suction turbine with 2 probe
Suction turbine with 3 probe
Suction turbine with 4 probe
Suction turbine with 6 probe
Choose Back
Fig. 64
Type of pellet feed system
Suction turbine with 8 probe
Suction turbine with mixer
Choose Back
Fig. 65
Operating time of
suction turbine
Actual value 30 sec.
min. 20 sec.
max. 70 sec.
Save Back +
Maximum value of set temperature
This is the maximum setpoint achievable in normal heating operation.
Factory setting: 75 °C
Setting range: 60 – 75 °C
Set temperature ext. heating requirement
This is the set temperature for external heating requirement.
Factory setting: 70 °C
Setting range: 35 – 75 °C
Type of pellet feed system
Setting for whether operation is without feed system, with 2 or 8 probes or with
mixer (buried tank).
Factory setting: without feed system
The following settings are available.
For changeover unit with 3 probes: Suction turbine with 2 probe
Suction turbine with 3 probe
For changeover unit with 8 probes: Suction turbine with 4 probe
Suction turbine with 6 probe
Suction turbine with 8 probe
For buried tank with mixer
and for solo probe: Suction turbine with mixer
Fig. 66
Ash removal profile
Stage 0
Stage 1
Stage 2
Stage 3
Save Back
Ash removal profile
This adjuster can be used to adjust the removal of ash from the burner pot for
different stages of pellet quality.
Factory setting: Stage 1
Information!
Restore factory setting for next delivery of pellets.
Stage 0 to Stage 3
very low proportion of ash very high proportion of ash
(possibly formation of slag)
no ash removal in
modulation mode
frequent ash removal in
modulation mode